Sign in or register to view your pricing and inventory.

Appleton EFSC150GFI GFI Factory Sealed Ground Fault Circuit Interrupter with Cover and Box; 125 Volt AC, 20 Amp

  • Appleton EFSC150GFI Appleton EFSC150GFI GFI Factory Sealed Ground Fault Circuit Interrupter with Cover and Box; 125 Volt AC, 20 Amp
  • Appleton EFSC150GFI GFI Factory Sealed Ground Fault Circuit Interrupter with Cover and Box; 125 Volt AC, 20 Amp
Manufacturer: Appleton
Mfr. #: EFSC150GFI
Item #: 132675
UPC: 781381671125
Login for Availability
Your Price:

Product Details

Arcing is confined within the device's interior sealed chamber

Detailed Description: Appleton GFI Factory sealed ground fault circuit interrupter with cover and box has a voltage rating of 125 VAC and a current rating of 20 Amps. It has smooth-operating test and reset buttons. It has malleable iron, cast copper-free aluminum cover with baked gray epoxy clad finish to offer durability and corrosion resistance. Interrupter has NEMA 3, 3R, 7BCD, 9EFG rated enclosure to offer added protection. Interrupter is UL listed.

Product Specification

Amperage Rating 20
Application For U-Line 20 AMP Receptacles
Brand Appleton
Catalog Description EFSR-GFI Series 1-Gang Ground Fault Circuit Interrupter, Voltage Rating: 125 VAC, Amperage Rating: 20 AMP, Frequency Rating: 50 - 60 HZ, Trip Type: 5 MILAMP Trip Setting, Enclosure: NEMA 3, 3R, 7BCD, 9EFG, Material: Malleable Iron, Mounting: Surface Mount With 1/2 IN Feed-Thru Hub, Standard: Class I, Group B, Class I, Groups C, D, Class II, Groups E, F, G, Class III, UL Listed: E81751, UL Standard: 943, 1203, For U-Line 20 AMP Receptacles
Enclosure NEMA 3, 3R, 7BCD, 9EFG
GTIN

00781381671125

Height 4.8000
Height Unit IN
Item Status A
Length 7.5000
Length UOM IN
Mfr. # EFSC150GFI
Special Features GFI cover and box; 5 MILAMP Trip setting; Provides required ground fault protection for portable electrically-operated devices; For ground fault protection in hazardous locations; Well suited for use in highly corrosive atmospheres and wet locations; Factory sealed construction; No external seals are required; Arcing is confined within the device's interior sealed chamber; Smooth-operating test and reset buttons; Can be installed in standard EFD Series mounting boxes; Cover bolts, test and reset buttons and shafts are made up of stainless steel
Standard Class I, Group B; Class I, Groups C, D; Class II, Groups E, F, G; Class III; UL Listed: E81751; UL Standard: 943, 1203
Type EFSR-GFI Series 1-Gang Ground Fault Circuit Interrupter
UNSPSC 39121565
Voltage Rating 125
Width 5.6000