Sign in or register to view your pricing and inventory.

Ferraz Shawmut R632 Fuse Reducer; 30 - 600 Amp, 250 Volt

  • Mersen R632 Ferraz Shawmut R632 Fuse Reducer; 30 - 600 Amp, 250 Volt
  • Ferraz Shawmut R632 Fuse Reducer; 30 - 600 Amp, 250 Volt
Manufacturer: Mersen
Mfr. #: R632
Item #: 91190
UPC: 782001752361
Login for Availability
Your Price:

Product Details

Fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings

The use of closer rated time-delay fuses can improve circuit protection

Allows 100 Amp fuse to fit 200 Amp clips

Detailed Description: Ferraz Shawmut Rejection type class R fuse reducer operates at a voltage rating of 250 VAC. It allows the use of lower rated fuses in existing equipment having clips with higher ampere ratings. Rejection-type reducers will allow only Class R fuses to fit Class R clips. It allows 30 Amps fuse to fit in 60 Amps clip, use of closer rated time-delay fuses can improve circuit protection. Fuse reducer is UL listed and CSA certified.

Product Specification

Application Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications.
Brand Ferraz Shawmut
Catalog Description Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications. R (250) Volts 30 Amps 60 series.
GTIN

00782001752361

Height 0.8120
Height Unit IN
Item Status A
Length 0.9200
Length UOM IN
Mfr. # R632
Standard 250V and 600V Class H, K, and R - UL Listed Guide No. IZZR, CSA Certified. 600V Class J - UL Listed Guide No. IZZR, CSA Certified 30-600A
Type Fuse Reducers
UNSPSC 39121627
Voltage Rating 250
Width 0.8120
Width UOM IN