Ferraz Shawmut 9F60FMH040 Amp-Trap® Power Fuse; 40E Amp, 15.5 Kilo-Volt

  • Mersen 9F60FMH040 Ferraz Shawmut 9F60FMH040 Amp-Trap® Power Fuse; 40E Amp, 15.5 Kilo-Volt
  • Ferraz Shawmut 9F60FMH040 Amp-Trap® Power Fuse; 40E Amp, 15.5 Kilo-Volt
Manufacturer: Mersen
Mfr. #: 9F60FMH040
Item #: 36309
UPC: 782001397142
Login for Availability
Your Price:

Product Details

Size: 3 Inch x 18.880 Inch

Power distribution current limiting fuses are designed not only to interrupt the high fault currents but also to interrupt low fault currents down to approximately 3 times their continuous rating

Detailed Description: Ferraz Shawmut Amp-Trap® EJ1 Point detonating fuse is made of metal that provides long lasting durability. It is a type of low resistance resistor that acts as a sacrificial device to provide overcurrent protection. Fuse is surrounded by air or by materials intended to speed the quenching of the arc and silica sand or non-conducting liquids are used. Fuse is designed to interrupt hig/low fault currents. Fuse operates at a voltage rating of 15.5 kilo-Volts.

Product Specification

Amperage Rating 40
Application Protection for 12 kV to 15.5 kV transformers or distribution systems.
Brand Mersen
Catalog Description Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips. 15500 Volts 40 amps FMH series.
Connection Ferrule
GTIN

00782001397142

Height 3.0000
Height Unit IN
Interrupt Rating 50
Item Status A
Length 18.8800
Length UOM IN
Mfr. # 9F60FMH040
Mounting Clip
Size 18.88 x 3
Special Features "Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment Ferrule mounting for standard clips and interchangeability with other brands of fuses Current-limiting for superior equipment protection Non-venting for silent operation Metal embossed catalog number and manufacturing date for lasting identification Outdoor usage for the 9F62 and 9F60 type EJO Blown-fuse indicator to give positive identification of open fuse: Amp-Trap: 2"" Barrel 1 lb tripped force - 0.19 Inch Amp-Trap: 3"" Barrel 2 lb tripped force - 0.50 Inch 9F60/9F62: 0.125 lb tripped force 0.20 Inch"
Standard Some UL listed to standard File E143362
Sub-Brand Amp-Trap
Type General Purpose Ferrule Mount Fuses for Transformer Protection
Type Of Indicators Visual Indicator
UNSPSC 39121626
Voltage Rating 15,500
Width 3.0000