Dimension: 3.390 Inch Length x 4.360 Inch Width x 2.960 Inch Height
Interleaved copper windings reduce I^2R losses and maximize efficiency
Din rail power supplies
Surge suppression devices provide additional protection and longevity to any electronic equipment
Integrally molded, flame retardant terminal blocks provide greater terminal contact area and improved conductivity
Mounting dimensions are compatible with similar control transformers
Detailed Description: Sola/Hevi-Duty E050TH SBE Series General purpose encapsulated control transformer measuring 3.390 Inch x 4.360 Inch x 2.960 Inch is epoxy encapsulated for cooler operation. 1-Phase transformer has 220 x 380 x 440, 230 x 400 x 460, 240 x 415 x 480 Volts primary and 120 x 240/115 x 230/110 x 220 Volts secondary, 50/60 Hz and 50 VA rating. It has din rail power supplies, surge suppression devices offers additional protection and longevity to any electronic equipment. It has integrally molded, flame retardant terminal blocks that offers greater terminal contact area and improved conductivity. Transformer can be used for industrial applications and is cULus listed, meets CE, NEMA, ANSI and IEC certified, RoHS complaint standards.
Application | Industrial |
Brand | SolaHD |
Catalog Description | International Series Control Transformer, 50VA, Volts Primary: 240/415, 277/480, 230/400/460, 220/380/440, Volts Secondary: 120/240, 115/230, 110/220, Frequency: 50/60 HZ |
Enclosure | IP20 |
Frequency Rating | 50/60 |
GTIN |
00783472002160 |
Height | 5.56 |
Height Unit | IN |
Item Status | A |
kVA Rating | 0.05 |
Length | 7.36 |
Length UOM | IN |
Mfr. # | E050TH |
Mounting | Heavy Gauge Steel Mounting Plate |
Number Of Phases | 1 |
Power Factor | 50 |
Primary Voltage | 240/415/480 Volt Primary |
Secondary Voltage | 120/240 Volt Secondar |
Special Features | "50-1,000 VA, 50/60 Hz, suitable for world wide applications. Interleaved copper windings reduce I2R losses and maximize efficiency. 55 DEGC/131 DEGF rise, 105 DEGC insulation system to minimize heat. Epoxy encapsulated to protect cores and coils against moisture, dirt, and other contaminants. Meets or exceeds NEMA Standard ST 1 and ANSI C89.1 for load inrush capability. Integrally molded, flame retardant (IEC 707/ISO Class 1210) terminal blocks provide greater terminal contact area and improved conductivity. Heavy gauge steel mounting plate. Mounting dimensions are compatible with similar control transformers. Secondary fuse holders (FB2X) included for 13/32"" x 1-1/2"" cartridges (fuses not included). Factory installed fuse holders are available (see WA and WB options)." |
Standard | cULus Listed: E77014, UL 506, CSA C22.2 No. 66, RoHS Compliant |
Type | International Series Control: 50-750 VA. |
UNSPSC | 39121026 |
Wattage | 750 |
Width | 6.38 |
Width UOM | IN |