Sign in or register to view your pricing and inventory.

Sola/Hevi-Duty DT651H14S Drive Isolation Transformer; 460 Volt Primary, 460Y/266 Volt Secondary, 14 KVA

  • Appleton DT651H14S Sola/Hevi-Duty DT651H14S Drive Isolation Transformer; 460 Volt Primary, 460Y/266 Volt Secondary, 14 KVA
  • Sola/Hevi-Duty DT651H14S Drive Isolation Transformer; 460 Volt Primary, 460Y/266 Volt Secondary, 14 KVA
Manufacturer: Appleton
Mfr. #: DT651H14S
Item #: 135799
UPC: 783472400164
Login for Availability
Your Price:

Product Details

Dimension: 14 Inch Length x 18 Inch Width x 23 Inch Height

Isolation minimizes load disturbances caused by the SCR drive

Taps on all units for adjustments to incoming source voltage

Full capacity secondary neutral as required by the national electric code

Shielding attenuates line to ground noise

Detailed Description: Sola/Hevi-Duty 3-Phase Drive isolation transformer used in SCR variable speed motor drive application magnetically isolates the incoming line from the motor drive. It also provides a voltage change to match the required voltage of the SCR drive. It is specifically designed to handle the mechanical stresses, voltage demands and harmonics associated with SCR applications. Transformer measures 14 Inch x 18 Inch x 23 Inch. It has primary voltage rating of 460 Volts delta, secondary voltage rating of 460Y/266 Volts and a frequency rating of 60 Hz. Transformer has a current rating 14 kilo-Amps. It has a power rating of 14 KVA. Isolation minimizes load disturbances produced from the SCR drive. It has shielding that attenuates line to ground noise. It has NEMA 3R rated weather shield enclosure. Transformer meets UL/CSA/cULus standards.

Product Specification

Application SCR Variable Speed Drives
Brand SolaHD
Catalog Description Drive Isolation Transformer, 14 kVA, Drive Horse Power 10, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
Enclosure Nema 3R with weather shield
Frequency Rating 60
GTIN

00783472400164

Height 23
Height Unit IN
Item Status A
kVA Rating 11
Length 14
Length UOM IN
Mfr. # DT651H14S
NEMA Frame Size NEMA 3R
Number Of Phases 3
Primary Voltage 460 Delta
Secondary Voltage 460Y/266
Special Features Isolation minimizes load disturbances caused by the SCR drive. Taps on all units for adjustments to incoming source voltage. Full capacity secondary neutral as required by the NEC.
Standard cULus Listed: E77014, UL 506, CSA C22.2 No. 66, Listed E25872, UL 1561
Type Drive Isolation Transformers: 7.5-440 kVA, Three Phase
UNSPSC 39121029
Width 18
Width UOM IN